Files:Technical information and downloadable documents 1
DiniArgeo SPO series single point load cells
A BL TECH specialist will confirm the price, lead time and technical fit.
Description
Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 300x300 mm.
C3 PRECISION CLASS
OFF CENTER LOAD COMPENSATED
ALUMINIUM ALLOY CONSTRUCTION
IP67 PROTECTION
MAX. CAPACITIES FROM 3 TO 40 kg
FOR PLATFORMS WITH DIMENSIONS UP TO 300 X 300 mm
SHIELDED CONNECTION CABLE
OIML AND TEST CERTIFICATES AVAILABLE UPON REQUEST
● Minimum load cell verification interval:
● Vmin = EMax/8.000-15.000
● Maximum number of verification intervals: nLC = 3000
● Full Scale Output: 2mV/V +/- 10%
● Temperature effect on zero:
from ±0,0093% F.S./10K to ±0,0175% F.S/10K
● Temperature effect on full scale output:
0,0117% F.S./10K (-10°C/+20°C) 0,0175% F.S./10K (+20°C/+40°C)
● Compensated Temperature Range: -10°C/+40°C
● Operating Temperature Range: -10°C/+50°C
● Maximum tolerated excitation voltage: 15 VDC
● Input Resistance: 300..500 Ohm
● Output Resistance: 300..500 Ohm
● Insulation Resistance: >2000 MOhm
● Safe Overload: 150% F.S.
● Ultimate Overload: 300% F.S.
● 4-wire shielded cable, 40cm long, 3,2mm diameter
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
● ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
● ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.